Product News

What to Look for in a Petroleum Distillation Tester — And How the HZ-662 Checks the Boxes
Walk into any petroleum quality-control lab and you'll find a distillation tester running almost every shift. It's not glamorous equipment, but get the setup wrong — wrong condenser temperature, sloppy volume readings, no safety net on a volatile fraction — and the data you send to a client or regulator becomes worthless at best, dangerous at worst.
Here's what actually separates a dependable ASTM D86 distillation tester from one that just looks the part.

Inside the GIS Partial Discharge Simulation System: A Testing Platform That Actually Matches Real Faults
Most partial discharge test benches stop at detecting whether PD exists. This one goes further — it shows you exactly which kind of discharge you're dealing with, under conditions close enough to real GIS operation that the data actually means something.
The transformer partial discharge free test system was designed around actual physical GIS architecture. That sounds obvious, but a lot of simulation rigs cut corners. Here, the internal layout, the SF6 environment, and the electrode geometry follow real-world configurations, so when you simulate a tip discharge or a free metallic particle moving inside the enclosure, the resulting signal isn't an approximation — it's what field engineers see on 110 kV to 500 kV equipment in service.

HZ-109S Primary Current Injection Tester: Fast, Accurate CT Ratio Testing

Capacitance and Tan Delta Tester: Catch Insulation Aging Before It Fails
Most high-voltage equipment doesn't fail without warning — it fails after months of slow insulation degradation that nobody measured in time. A capacitance and tan delta tester (also called a dissipation factor or power factor tester) is how field engineers catch that drift early, by tracking the dielectric loss and capacitance of transformers, bushings, CTs, PTs, capacitors, and surge arresters before a small defect turns into an outage.

One-Stop Solution for Cable Health Diagnosis
Hauling a hipot set, a separate tan delta bridge, and a partial discharge coupler to the same job site is the kind of overhead that adds hours to a cable commissioning schedule. That's the problem an all-in-one VLF tester with PD and tan delta is designed to solve — and it's why this category has grown so quickly in power utilities, petrochemical plants, and railway electrical maintenance programs.

HZXB-1000kVA/500kV Variable Frequency Series Resonance Test System: Field AC Withstand Testing for Cables, GIS, and Transformers
Commissioning crews working on 10 kV through 220 kV projects rarely have room for a full-size power-frequency test transformer. A variable frequency series resonance test system solves that by tuning the supply (typically 30–300 Hz) until the reactor inductance and the test object capacitance resonate. Input power then tracks real losses—not the full reactive burden—so a 1000 kVA-rated set can realistically handle long XLPE cable runs and bulky GIS modules on site.

Transformer Test Bench for Oil-Immersed & Dry-Type Transformers: Full-Spectrum Testing in One System
Not every transformer test bench is built to handle the full range of units coming off a production line. This one is.
Designed for distribution and power transformer manufacturers, independent testing labs, and quality certification facilities, this integrated transformer test system covers oil-immersed transformers up to 63,000 kVA at 110 kV — including S9, S11, S13 series and amorphous alloy cores — dry-type transformers up to 31,500 kVA at 35 kV, and mine explosion-proof transformers rated up to 6,300 kVA at 10 kV. Special transformer configurations (rectifier, furnace, traction) can be accommodated on request with specific capacity and voltage details provided at order.

Choosing a Transformer Turns Ratio Tester: A Field-Tested Look at the HZBB-10B
Ask any commissioning engineer and they'll tell you the same thing: a transformer turns ratio test sounds simple, but doing it right in a noisy substation is another story. That's where the HZBB-10B transformer turns ratio tester earns its keep.

Cable Fault Location: A Field Engineer's Complete Guide
Ask any cable crew what eats their day, and it's rarely the repair itself — it's finding the fault before the digging starts. A buried fault on a medium-voltage feeder doesn't announce its position. Get the location wrong by even a few meters and you've opened the wrong stretch of road. So the real skill isn't repair; it's working a structured location process and trusting the right instrument at each step.
Step one: classify the fault before you chase it
Start with an insulation resistance test to sort what you're dealing with — open circuit, short circuit, low resistance, high-resistance leakage, or a high-resistance flashover fault. The fault type dictates the method. Skip this and you'll waste an hour applying the wrong technique to the wrong fault.
Step two: pre-locate the distance
This is where rough distance measurement happens. A low-voltage pulse method (TDR) handles open and short-circuit faults cleanly, reading the reflection off the impedance change. But low-voltage pulses can't see high-resistance faults — that's where the flash current method (arc reflection) and the multiple pulse method earn their place. A surge generator ignites a brief arc at the fault, momentarily converting a high-resistance fault into something the reflectometer can read.
A trolley-type integrated system is built exactly for this back-and-forth. Embedding the distance-measurement unit, a high-frequency high-voltage supply (negative output ≤32kV), and a multiple-pulse generator into one anti-interference chassis means you're not dragging four separate boxes across a substation yard. One discharge from the multiple pulse generator produces ten low-voltage waveforms, and the software auto-selects the standard one — cutting through oscillation noise that normally forces you to re-shoot. With eight sampling frequencies from 3.125MHz to 400MHz and a 5m–100km test range, the host reads the inflection point and displays fault distance automatically.
Step three: pinpoint the exact spot
Distance gets you close; pinpointing gets you the dig. An ultra-quiet fixed-point instrument using acoustic-magnetic synchronization measures the time gap between surge and sound — that interval drops to a minimum directly over the fault, which beats chasing raw volume. With BNR background noise reduction and ±0.2m accuracy, it works on lawn, asphalt, and hardened pavement alike.
Light, integrated, and ground-loop protected — that's what turns a long outage into a one-shot location.

How to Extend Transformer Life by 20% with Routine Testing?
Every transformer failure that could have been caught during a scheduled outage window has at least one thing in common: the routine test wasn't done thoroughly enough. The turns ratio test (TTR) sits at the top of most commissioning and field maintenance checklists for good reason — it's non-destructive, it doesn't stress the insulation system, and when all three measurement outputs are read correctly, it reveals more about winding condition than almost any other routine test.