- Energy Meter Field Calibrator
-
Transformer Test Equipment
- Transformer Test Bench
- Turns Ratio Tester
- DC Resistance Tester
- Transformer Tan Delta Tester
- Sweep Frequency Response Analyzer
- Partial Discharge Tester
- CT PT Analyzer
- Transformer On-Load Tap-Changer Tester
- Short-Circuit Impedance And No-load Integrated Tester
- Winding Resistance And Turns Ratio Integrated Tester
- Transformer Capacitance And Inductance Tester
- Transformer Capacity And Characteristic Tester
- Lightning Arrester Tester
- Short-Circuit Impedance Tester
- Transformer Oil Test Equipment
- SF6 Gas Analyzer
- Secondary Injection Relay Test Set
- Resistance Tester
- Power Quality Analyzer
- HV Switch Tester
- High Voltage Test Equipment
- Cable Fault Locator
- Battery Tester
Huazheng Variable Frequency Series Resonance Test Device Ac Resonance Test System
Product apply range and features
1. 150kV power cable test
Capacitance to be tested: frequency at 30-300HZ, capacitance to
bestested 0.35uF.
The test voltage is no more than 150kV, and the running time is 60min.
2. 150kV HV switch GIS test
Capacitance to be tested: frequency at 30-300HZ, capacitance to be
tested: 0.0885uF.
The test voltage is no more than 300kV, and the running time is 1min.
3. 28KV/800MVA generator test
Capacitance to be tested: frequency at 30-300HZ, capacitance to
bestested 0.35uF.
The test voltage is no more than 59kV, and the running time is 1min.
Working environment
Operation condition
1. Rated capacity: 1500kVA;
2. Input power: three-phase 380V voltage, 50Hz frequency;
3. Rated voltage: 150kV; 300 kv
4. Rated current: 10A; 5 A
5. Working frequency: 30-300hz;
6. Device output waveform: sine wave
7. Waveform distortion rate: Output voltage waveform distortion rate ≤ 1%;
8. Working time: allowed for 90min continuously under the rated
load; ;Overpressure 1.1 times 1 minute;
9. Temperature rise: after running 90min under rated load, the temperature
rise is ≤25K;
10. Quality factors: the device itself Q ≥ 30 (f = 45Hz);
11. Protection function: the test product has over-current, overvoltage and
test flashover protection (see the variable frequency power section);
12. Measurement accuracy: system RMS 1.5;
Standards
Components
1.JLB-120kVA/6/12/18/24/30kV/0.4kV Exciter transforemer 1 pc
2.HZXB-F -120kW/380V variable frequency power supply 1 pc
3. DK-750kVA/150kV HV frequency variable reactor 2 pcs
4.FR-300kV/1000pF capacitive divider 1 pc

Device capacity determination
TO KNOW MORE ABOUT Huazheng, PLEASE CONTACT US!