- Energy Meter Field Calibrator
-
Transformer Test Equipment
- Transformer Test Bench
- Turns Ratio Tester
- DC Resistance Tester
- Transformer Tan Delta Tester
- Sweep Frequency Response Analyzer
- Partial Discharge Tester
- CT PT Analyzer
- Transformer On-Load Tap-Changer Tester
- Short-Circuit Impedance And No-load Integrated Tester
- Winding Resistance And Turns Ratio Integrated Tester
- Transformer Capacitance And Inductance Tester
- Transformer Capacity And Characteristic Tester
- Lightning Arrester Tester
- Short-Circuit Impedance Tester
- Transformer Oil Test Equipment
- SF6 Gas Analyzer
- Secondary Injection Relay Test Set
- Resistance Tester
- Power Quality Analyzer
- HV Switch Tester
- High Voltage Test Equipment
- Cable Fault Locator
- Battery Tester
Huazheng OEM HZ5375 5000A Digital Primary Current Injection Tester Supplier
Performance characteristics
⑴Aesthetic and elegant PVC panel
⑵ Directly display the test values of primary current and secondary current, which is convenient for experimental observation and recording.
(3) Secondary measurement, turn ratio and polarity display of CT PT
⑶High measurement accuracy:0.5 level
⑷High power, small size, strong load capacity
⑸ Small size and light weight, the volume is only 30% to 70% of similar products, so it is very convenient to carry.
Technical Characteristic
1.Name and Classification
(1) Name: HZ5375 5000A Primary Current Injection Tester.
(2) Environmental group: It belongs to the group III instrument in GB6587.1-86 "General Survey of Environmental Measurement of Electronic Measuring Instruments" (that is, it can be used in outdoor environments).
(3)Input voltage: AC380V ±10%
(4)Power :36KVA
(5)Output current: AC0~5000A stepless adjustable, panel with digital display ammeter
(6)Output voltage:6V
(7) Output waveform: The output current is a standard sine wave with small glitches, which
is better than the power system requirements index standard, and the ripple coefficient is less than 0.3%. Standard sine wave
(8) Measurement accuracy: (Using 0.2S grade material) The actual is about 0.3; each current can be smoothly and continuously adjusted, the accuracy is higher than 0.5. The current and voltage meter shows true and effective value, high accuracy and high stability.
(9)Output current mode: true effective value is continuously adjustable;
(10)Current stability: 0.2%
(11)Structural form: Fission
(12)Wiring method: according to requirements
(13)Protection settings: overcurrent and overvoltage;
2.Operating
(1) After the wiring is completed, you should check it again to see if there is a wiring error and whether the connector is in good contact.
(2) During the test, if there is a fire, and there is no abnormality such as no display when starting up, immediately turn off the power and recheck the wiring.
(3) During actual wiring, the current output terminal should form a loop, otherwise the instrument will not output current.
(4) The current riser is provided with a random output wire; the output external copper wire is selected according to 10A/mm2. (Standard configuration is two 3-meter test lines)
(5) The capacity of the equipment is designed for one hour operation.
Working Principle
Working principle
(1). The measuring circuit of the instrument includes a current measuring circuit and a current measuring circuit. (Voltage test can be added as required) The volt ampere characteristic function can be expanded.
(2). The current measuring circuit includes micro current zero impedance CT, programmable amplifier circuit and sampling circuit.
(3). The voltage measurement circuit includes PT isolated signal acquisition circuit, programmable amplifier circuit and sampling circuit.
(4). The 16 bit single-chip microcomputer uses the computer digital real-time acquisition method to calculate the high-voltage voltage measurement value by measuring the amplitude of the voltage signal according to the voltage proportional relationship. The automatic timing function is realized by comparing the measured voltage signal amplitude with the set voltage value. The current output of the device can be calculated according to the current proportional relationship, The over-current protection function is realized by measuring the amplitude of current/voltage signal and comparing it with the set value.
Safety Precautions
1. Principle Block Diagram
(1) For the safety of operators and instruments, ensure that the instruments are well grounded.
(2) The ground wire shall be connected first when preparing for the test, and the ground wire shall be removed finally when the work is completed.
(3) The power supply connected to the instrument shall be able to withstand 30A current impact.
(4) When connecting the instrument and the test object, pay attention to check whether each wiring is wrong to avoid damage to the equipment due to wiring errors.
(5) The maximum current value set for overcurrent protection shall not exceed the rated output current value of the instrument.
(6) Do not plug or unplug any wires when the power is on.
2. Working Principle
The instrument's measurement circuitry includes one current measurement loop and another (voltage measurement can be added as required). The volt-ampere characteristic function can be extended.
The current measurement loop comprises a micro-current zero-impedance CT, a programmable amplification circuit, and a sampling circuit.
The voltage measurement loop includes a PT isolation signal acquisition circuit, a programmable amplification circuit, and a sampling circuit.
A 16-bit microcontroller employs a computerized digital real-time acquisition method. By measuring the amplitude of the voltage signal, the high-voltage side voltage value can be inferred based on the voltage proportional relationship. The automatic timing function is realized by comparing the measured voltage signal amplitude with the set voltage value. The current output size of the device can be calculated based on the current proportional relationship. Overcurrent protection is achieved by comparing the measured current/voltage signal amplitude with the set value.
Transportation And Maintenance
1.Transportation
This product must be packed during transportation. The packing box shall be wooden and shall be padded with foam and other anti vibration layers. The packaged products shall be able to be transported by road, railway and air. During transportation, it shall not be placed in the open trunk, and the warehouse shall be protected against rain, dust and mechanical damage.
2.Storage
The instrument shall be stored in a ventilated room with an ambient temperature of - 40 ℃~60 ℃, a relative humidity of no more than 82%, and no corrosive gas. It shall not be placed close to the ground and wall.
3.moisture-proof
In humid areas or humid seasons, if the instrument is not used for a long time, it is required to turn on the power once a month (about two hours), so as to distribute moisture and protect electronic components.
4.Anti-Insolation
When the instrument is used outdoors, avoid or reduce direct sunlight exposure to the display screen as much as possible, and do not put it in a particularly humid warehouse.
Quality Assurance And After-Sales Service
1. The instrument is manufactured in strict accordance with national standards and enterprise standards, and the production process strictly complies with ISO9000 standards to ensure the quality of the instrument.
2. The instrument has a 1-year warranty period. During this period, if the quality is lower than the characteristic requirements due to manufacturing reasons, the company will repair it free of charge.
3. This instrument implements three guarantees.
4. Within the service life of the instrument, the company will provide long-term maintenance, training, accessories supply and other related services.
5. If problems are found in use, please contact our company in time. We will take different methods according to the situation: door-to-door maintenance guidance, or return to the factory for maintenance.



TO KNOW MORE ABOUT Huazheng, PLEASE CONTACT US!
Our experts will solve them in no time.






