- Energy Meter Field Calibrator
-
Transformer Test Equipment
- Transformer Test Bench
- Turns Ratio Tester
- DC Resistance Tester
- Transformer Tan Delta Tester
- Sweep Frequency Response Analyzer
- Partial Discharge Tester
- CT PT Analyzer
- Transformer On-Load Tap-Changer Tester
- Short-Circuit Impedance And No-load Integrated Tester
- Winding Resistance And Turns Ratio Integrated Tester
- Transformer Capacitance And Inductance Tester
- Transformer Capacity And Characteristic Tester
- Lightning Arrester Tester
- Short-Circuit Impedance Tester
- Transformer Oil Test Equipment
- SF6 Gas Analyzer
- Secondary Injection Relay Test Set
- Resistance Tester
- Power Quality Analyzer
- HV Switch Tester
- High Voltage Test Equipment
- Cable Fault Locator
- Battery Tester
0102030405
Huazheng Manufacture HZ-109S Primary Current Injection Test Set Price
I. The Main Performance Index
2.1 Input Power Supply: AC:220V·25A,50Hz.
2.2 Output Current: AC:1000A·5V or 500A·10V.
2.3 LCD Screen Digital Display: Simultaneous display of primary current and secondary current as well as the turn ratio;
The Range of Primary Current: 01100A, Resolution:0.1A;
The Range of Secondary Current: 0~6A; Resolution:0.001A.
Stopwatch: 0.0001~999.99S precision ±5 significant figures.
2.4 Precision: TRUE RMS 0.5%.
2.5 Duplicate Protection (electronic overload protection and software protection).
2.6 Usage Environment: Temperature -1040℃,
Relative humidity <80%.
2.7 Volume; 430×260×260mm3.
2.8 Weight: 28kg.
II.Principle Of Operation
The circuit is shown in the figure below. Input from X5 and X6 (AC 220V) power flows through the main switch (KG), is adjusted by the voltage regulator (TY), controlled by K1, and then amplified. The large current is output via the current transformer from X1 and X4. The two parallel coils will output a 1000A current, with a maximum no-load voltage of 5V. Meanwhile, the two series coils will output a 500A current, with a maximum no-load voltage of 10V.
The ARM controller handles the data display for the mouse and signal panel, manages the output of the stopwatch (connection positions or electric potential), and controls the system.
III.Output Time Ratio
|
Output Time Ratio of High Current Tester |
|
|
Rated Current |
Time(s) |
|
110% |
10S |
|
100% |
60S |
|
90% |
90S |
|
80% |
120S |
|
70% |
240S |
|
60% |
600S |
|
50% |
1800S |
|
40% |
3600S |
|
<30% |
Long Time |



Packing List
|
No. |
Item |
Qty |
|
1 |
Main engine |
1 |
|
2 |
Test line |
2 |
|
3 |
Power line |
1 |
|
4 |
Double core sheathed wire |
2 |
|
5 |
Ground lead |
1 |
|
6 |
Small clip |
5 |
|
7 |
Insert |
1 |



TO KNOW MORE ABOUT Huazheng, PLEASE CONTACT US!