Huazheng HZTTR80A Transformer Turns Ratio Tester With Excitation Current
I.Main Functional Features
1.PT Ratio and Polarity Testing: Capable of measuring potential transformer (PT) ratio and polarity.
2.Blind Test Function: Equipped with a blind test function to accurately measure the ratio and connection group of a three-phase transformer, even when the connection group is unknown.
3.Transformer Compatibility: Capable of testing various types of transformers, including autotransformers, Z-type transformers, and phase-shifting transformers.
4.Tap Mode Settings: Added settings for high-voltage and low-voltage tap positions to accommodate transformers with taps at different voltage levels.
5.Low-Voltage Side Tap Settings: Includes settings for transformers with taps on the low-voltage side.
6.Graphical Display: Features a graphical interface for more intuitive readings.
7.Three-Phase Testing: Enables simultaneous measurement of three-phase ratios during three-phase transformer testing, significantly increasing testing speed.
Panel Description

1.Grounding Terminal: Before conducting any tests, please safely ground the grounding terminal to avoid the risk of electric shock.
2.Power Socket and Switch: The power input port for the entire device, used to connect or disconnect the test power supply.
3.High-Voltage Side Terminals: Yellow, green, and red terminals for connecting to the A, B, and C phases of the high-voltage side of the transformer under test.
4.Low-Voltage Side Terminals: Yellow, green, and red terminals for connecting to the a, b, and c phases of the low-voltage side of the transformer under test.
5.RS232 Communication Interface: Interface for computer communication.
6.Printer: Prints test results.
7.USB: Connects to a USB flash drive for data export.
8.Display Screen: 7-inch high-definition color touchscreen LCD with adjustable backlight for displaying the operation menu and test results.
II.Technical Parameters
Test Range: Transformation Ratio -- 0.9 to 10000, Current -- 0 to 2000mA, Angle -- 0 to 360°
Ratio Accuracy:
5V Range: ±(0.1% + 2 digits) (0.9-50), ±(0.2% + 2 digits) (51-200), ±(0.5% + 2 digits) (201-600)
80V Range: ±(0.1% + 2 digits) (0.9-500), ±(0.2% + 2 digits) (501-2000), ±(0.5% + 2 digits) (2001-10000)
Current Accuracy: ±(1% of reading + 0.5 mA)
Angle Accuracy: ±0.2°
Output Voltage: Selectable 5V or 80V
Resolution: Ratio -- Minimum 0.0001, Current -- 0.001mA, Angle -- 0.01°
Test Voltage: AC 5V @ 1A, AC 80V @ 80mA
Operating Power Supply: 220V AC, 50/60 Hz, Input Range: 100V to 240V
Ambient Temperature: -10°C to 40°C
Relative Humidity: ≤85%, non-condensing
Dimensions: Main Unit: 360290170(mm), Cable Box: 360290170(mm)


Packing List
|
No. |
Item |
Qty |
|
1 |
Host |
1 |
|
2 |
Test Cables |
1 |
|
3 |
Power Cord |
1 |
|
4 |
Operation Manual |
1 |
|
5 |
Certificate of Conformity |
1 |
|
6 |
Fuse |
2 |
|
7 |
Printing Paper |
1 |
|
8 |
Packing List |
1 |
|
9 |
Ground wire |
1 |
|
10 |
Serial cable |
1 |


TO KNOW MORE ABOUT Huazheng, PLEASE CONTACT US!
Our experts will solve them in no time.