get a quote
Inquiry
Form loading...
Products Categories
Featured Products

Huazheng HZJY-30K 30kv Insulation Resistance Tester

The insulation resistance tester, also known as a digital insulation resistance tester, megohmmeter, or intelligent insulation resistance tester, is suitable for insulation testing in the maintenance, repair, testing, and calibration of various electrical equipment.

This instrument features a clear and uniform insulation resistance scale, simple operation, easy portability, low power consumption, a long service life, and a battery capacity check function. It is ideal for measuring the insulation resistance of transformers, mutual inductors, generators, high-voltage motors, power capacitors, power cables, lightning arresters, and other electrical devices.

    30kv Insulation Resistance Tester   (5)

    I. Features

    High-voltage insulation resistance tester, with 8 range: 500V, 1000V, 2500V, 5000V, 10000V, 15000V, 20000V, 25000V, 30000V,test up to 30TΩ, manual voltage regulation function.
    ● Strict accordance with the safety standards for design
    ● Insulation resistance range 30TΩ @ 30 kv
    ● Short circuit current can be adjusted, maximum 5mA (Can be ordered as high as 10mA, short circuit current products).
    ● Automatic display polarization index (PI), induced electric absorption test values than (DAR), and can test the leakage current and capacitance.
    ● Anti-jamming performance is superior, the interference current reaches 2 mA, still ensure accuracy of test instruments.
    ● 2 methods for power: use of lithium ion batteries, battery life can be up to 4 hours (10000V @ 100MΩ).
    ● Insulation resistance simulation column.
    ● Digital filtering functions, external influence deviation display value causing mitigation point using filter function.
    ● Perfect protection function, and the spare fuse prompt functions.

    II.Specification Parameter

    ● Safety Standard
    IEC 61010-1    CAT.IV  600V
    IEC 61326      EMC specification: test, control and electrical equipment for testing
    IEC60529 IP64 (Outer closed state)
    ● AC Power:220V±10%,50/60 HZ ,20 VA
    ● battery:16.8V Lithium ion rechargeable battery 
    ● Battery Life:10000V@100M, 4 hour 
    ● size(L x W x H):37cm x 27cm x 14cm
    ● weight:3.6kg
    ● Test voltage accuracy: the nominal value  100% to 110%
    ● Voltage measurement accuracy:5%+3V
    ● Current test range:10mA
    ● current measure precision:5%+0.2nA
    ● short-circuit current: 5mA
    ● Capacitance test range:20uF
    ● Capacitance testing accuracy:15%+0.03uF
    ● Insulation resistance testing range and accuracy (T:23±5ºC ,RH :45 – 75%)

    range/

    accuracy

    500V

    1000V

    2500V

    5000V

    10000V

    Unspecified

    <1M

    <1M

    <1M

    <1M

    <1M

    5%

    1M -10G

    1M -20G

    1M -100G

    1M -100G

    1M -200G

    20%

    10G -100G

    20G-200G

    100G-1T

    100G-1T

    200G-2T

    Unspecified

    > 100G

    > 200G

    > 1T

    > 1T

    > 2T

    range/

    accuracy

    15000V

    20000V

    25000V

    30000V

    Unspecified

    <1M

    <1M

    <1M

    <1M

    5%

    1M -300G

    1M -400G

    100k-200G

    100k-200G

    20%

    300G -3T

    400G-4T

    200G-2T

    200G-2T

    Unspecified

    > 3T

    > 4T

    > 2T

    > 2T

    30kv Insulation Resistance Tester   (6)
    30kv Insulation Resistance Tester   (1)

    III.Instrument using

    • measured DAR:
    1.Select more than 1 minute length measurement.
    2.Select the appropriate voltage and start.
    3.The instrument automatically record 15 s and 60 s resistance, and calculate the absorption than after 60 seconds.
    Absorption ratio calculation method: DAR = R60 / R15;
     measured PI :
    1.Select more than 10 minute length measurement.
    2.Select the appropriate voltage and start.
    3.The instrument automatically record 15S, 60S and 600S resistance, and calculate the polarization index after 600 seconds.
    Polarization index calculation method : PI= R600/R60;
     test connection points for attention
    1. Tested to confirm product safety grounding, try not charged.
    2. Confirm the instrument E end (ground) have been grounded.
    3. The use of G terminal (protection ring) (this machine is of low voltage side of the screen)
    When measuring high insulation resistance, the sample should be in the position a conductor surface protection between the two measuring end ring, and the conductor protection ring is connected to the instrument with a test line G side, try to eliminate the measuring error caused by the surface leakage current, security testing is accurate.

    V. Packing List

    No.

    Item

    Qty

    1

    The high-pressure silica gel test line (red, green and black one)

    1

    2

     AC power line

    1

    3

    Red high voltage shielded wire

    1

    Transformer Ttr Meter (1)
    变压器测试系列
    Transformer Capacity Characteristic Tester  (1)

    TO KNOW MORE ABOUT Huazheng, PLEASE CONTACT US!

    Our experts will solve them in no time.