- Energy Meter Field Calibrator
-
Transformer Test Equipment
- Transformer Test Bench
- Turns Ratio Tester
- DC Resistance Tester
- Transformer Tan Delta Tester
- Sweep Frequency Response Analyzer
- Partial Discharge Tester
- CT PT Analyzer
- Transformer On-Load Tap-Changer Tester
- Short-Circuit Impedance And No-load Integrated Tester
- Winding Resistance And Turns Ratio Integrated Tester
- Transformer Capacitance And Inductance Tester
- Transformer Capacity And Characteristic Tester
- Lightning Arrester Tester
- Short-Circuit Impedance Tester
- Transformer Oil Test Equipment
- SF6 Gas Analyzer
- Secondary Injection Relay Test Set
- Resistance Tester
- Power Quality Analyzer
- HV Switch Tester
- High Voltage Test Equipment
- Cable Fault Locator
- Battery Tester
Huazheng HZCS-N3 Astm D974 Transformer Oil Acidity Number Testing Machine
Features
I. Overview and Technical Index
1. Overview
HZCS-N3 transformer oil acid tester is a fully automatic measuring instrument which adopts the extraction method to accurately detect the insulating oil acid value. This instrument can improve the working efficiency and test accuracy, and at the same time ensure the safety of the body by reducing the operator's contact with the samples and reagents.
The instrument will automatically search the samples, inject the extraction, make a blank titration, do an experiment, clean off, display printing results and other operations as long as the operator put the sample cups in the sample cup holes and inject the extraction in the cup. Once started, 1 to 3 samples can be measured, which is convenient and high efficiency.
Because of the preparation of the standard acid for instrument calibration and calibration procedure, the clients can calibrate the instrument and the neutralizing liquid at any time so that the instrument can overcome the defect of changes in concentration of neutralizing liquid during use. At the same time, during the test the instrument will automatically deduct the background value of the extract so that the instrument can ignore the influence from the change of background value on the extraction. All these design make the result more accurate and reliable.
2. Technical index
1) Test range: 0.002~1mg KOH/g
2) Test error: ≤±0.005mg KOH/g
3) Repeatability: ≤0.005mg KOH/g
4) Ambient temperature: 10℃~45℃
5) Relative humidity(RH): ≤85%RH
6) Voltage supply: AC220V/50Hz
7) Power: 50W
I. Structure and Installation
1. 
Host structure
2.Installation
1) After unpacking, put the instrument in a stable laboratory bench. Then check whether the parts are damaged or not, and whether the random accessories are complete.
2) Connect the power supply.
Note:The instrument must be adequately grounded.
Packing List
No. |
Item |
Qty |
1 |
Main engine |
1 |
2 |
Neutralization liquid medicine |
2 |
3 |
Extracted liquid medicine |
2 |
4 |
Gas washing bottle medicine |
1 |
5 |
Indicator |
1 |
6 |
Standard acid |
1 |
7 |
Microsyringe |
1 |
8 |
Sample cup |
3 |
9 |
Stirrer |
3 |
10 |
Glass bottle |
3 |
11 |
Glass bottle cap |
3 |
12 |
Tubing for Peristaltic Pumps |
1 |
13 |
Print paper |
2 |
14 |
Power line |
1 |







TO KNOW MORE ABOUT Huazheng, PLEASE CONTACT US!
Our experts will solve them in no time.






