Huazheng HZCF-400 Intelligent Battery Charge and Discharge Tester

Battery Load Bank is a special instrument for the test of NiCD and Lead-acid storage battery string of the whole string voltage of 24V, 48V, 110V, 220V, and it adopts current advanced testing technology theory, and has obtained a series of breakthrough in research and application of new technology, new parts, new material and new techniques, which is designed in accordance with the requests of national related testing and maintenance regulations and it is a special detection instrument for the performance detection of stationary battery. Its big discharge power, small volume, light weight, complete function of data management software of upper computer could greatly reduce the work load of daily testing and maintenance of stationary battery.

    Handheld Capacitance Inductance Tester (2)

    I.Main Functions and Features 

    • The product is utilized color touch screen. It can be operated via finger or the touch pen with convenience and flexibility.
    • Data save mode: Internal save and external save(SD Card )
    • Enhanced over voltage protecting function , 
    • Automatically recovery the over current protecting function 
    • Overheating protection .

    II.Discharge Function

    The discharge function allows for discharging at a constant current using an intelligent dummy load after the battery string is removed from the system. Parameters such as “discharge current,” “discharge time,” “discharge capacity,” “final protective voltage of the whole string,” and “final protective voltage of the cell” should be set. The tester will then automatically carry out the discharge process and display real-time data including discharge current, battery discharged capacity, whole string voltage, cell voltage, discharge time, etc. If the string reaches the set values for final discharge voltage, final discharge capacity, final discharge time, or if any cell voltage falls below the set value for final cell voltage, the discharge test can be stopped either automatically or manually.
    It can save up to 10 sets of discharge test data, and users can perform query, deletion, and export operations using an SD card.
    The computer can connect to the instrument via serial communication to control tests, monitor the instrument in real-time, and perform graphical analysis.

    III.Automatic protection function

    1.The tester will automatically stop the test if it detects any abnormalities in the whole battery string or individual cells, or if it detects a malfunction in the tester itself, to protect the battery during the test process.
    2.The host machine of the tester integrates the monitoring and power sections. The power section uses high-efficiency, new-type components, making it a compact, high-efficiency comprehensive tester for storage batteries.
    3.The user-friendly interface is easy to operate with a clear flow, and each operation provides English prompts. The tester features an aquamarine blue, high-brightness, large-screen LCD with a clear and visually appealing display.
    4.The upper computer data management software offers powerful functions with a user-friendly interface, enabling data management, printing, report analysis and statistics, and the automatic creation of test reports.

    Test Procedure Introduction

    Discharge Test Procedure: 
    Step1: Pull“ On” on the discharge switch ( to prevent reverse connection of the discharge cable and damage the tester , and also if misconnection, the warning will be given.)
    Step2: Connect the discharge cable to the the host machine and battery bank respectively. ) Note: Red line is + positive ; Black line : - Negative ) reverse connection will be warning . ( See details in section 2.5 )
    Step 3: Connect group voltage test line to the two poles of battery string.
    Step 4: Plug in and switch on the tester.
    Step 5 : Enter into discharge test parameters setup.( see details in 3.2) 
    Step 6: Pull “ off”on the discharge switch . 
    Step 7: Press “ ok” start test 

    Junction port introduction 

    1

    Statement

    Our company will continuously improve and enhance the technical performance of the stationary battery comprehensive tester. At the same time, this manual may be updated as the product evolves, and some content may change. If changes occur, no additional notice will be given.
    The full technology behind the stationary battery comprehensive tester is exclusively owned by Foresight Electronics Technology Co., Ltd. No individual or entity is permitted to make alterations to it. The purpose of this product is to assist customers in the detection and maintenance of the stationary battery comprehensive tester. Any illegal use of this product will result in our company pursuing legal action.
    tester (3)
    Handheld Capacitance Inductance Tester (1)

    TO KNOW MORE ABOUT Huazheng, PLEASE CONTACT US!

    Our experts will solve them in no time.