0102030405
Huazheng HZCD-300(10V-160V 60A) Battery Charge Device

I.Main Functions and Features
1.The seven-inch color touch liquid crystal display offers a clear and vibrant display. The user-friendly interface is in Chinese, making it easy to read and operate, combining both beauty and practicality.
2.Charging Function: The charger automatically charges according to the battery's charging characteristic curve. The charging mode is designed as "constant current (uniform charge and voltage stabilization), constant voltage, and current reduction (which automatically switches to trickle floating charging)." This mode offers fast charging, high charging efficiency, and eliminates the need for manual intervention. It also prevents overcharging over extended periods. Users can set parameters such as average charging voltage, floating charging voltage, charging current, charging time, and charging capacity. The charger automatically performs the charging process and displays real-time information such as charging current, charging capacity, overall voltage, and charging time. Charging settings can be modified during the process. The charging operation can be stopped when the charging time reaches the set limit, the charging capacity reaches the set value, the charging module detects an abnormality, or if the operation is manually terminated.
3.Data Storage and Query Function: In the event of a sudden power loss or long-term inactivity, memory data in the host computer will not be lost. Up to 999 sets of charging data can be saved, and users can query, delete, or export the data via an SD card.
4.Equipped with PC data management software, it provides functions for data management, printing, analysis, report statistics, and the automatic generation of test reports.
5.It is compact, lightweight, and powerful. All connections feature fast-connect functionality, making the device easy to operate, quick, safe, and reliable.
II.Technical parameter
Product Model | HZCD-300(10V-160V 60A) |
Charging Power Supply | AC380V, 50HZ, three-phase four-wire system |
Rated input power | 10KW |
Instrument working power supply | AC220V |
Display mode | 7 inch color touch liquid crystal display |
Charging unit | High Efficiency Intelligent High Frequency Switching Power Supply |
Battery type | Lead-acid battery, alkaline battery |
Charging mode | Battery Disengagement System |
Charging current | 1~60A |
Charging Current Accuracy | Resolution 0.1A Accuracy 1A |
Charging Voltage Range | 10~160V |
Accuracy | Resolution 10 mV accuracy 0.1V |
Charging time | 0-99 hours 59 minutes |
Alarm generation and safety measures | The polarity of the test line is reversed; the charging current exceeds the set value; the voltage is higher than the set value; the temperature is abnormal; the instrument can automatically alarm and stop charging |
working temperature | -20~55℃ |
relative humidity | 90%(40±2℃) |
atmospheric pressure | (70~106)kPa |
III.Maintenance And Notices
Prompt Message
1.Cell module communication anomaly:
Please check whether the module is functioning correctly.
2.Internal storage data cannot be exported or there is an error when opening data on the host computer:
Please verify that the SD card is properly inserted and not damaged. If necessary, replace the SD card and retest.
3.Touch screen calibration issue:
Please recalibrate the touch screen.
Notices
1.The test equipment should be placed in an environment with good ventilation, free from corrosion and strong electromagnetic interference. Ensure that the ventilation holes on both the front and rear of the main engine box are not blocked to maintain proper airflow.
2.When the test instrument is in use, the plug connection should not be used for charging, as this could cause damage to the tester.
3.Please strictly follow the user manual for operation. Do not engage in improper or harsh charging operations.
4.Avoid bumping or subjecting the product to serious impacts during transportation.
5.When storing the product, ensure it is kept in a dry environment and away from fire hazards.
6.Specifications and descriptions may have slight differences from the actual product. Please refer to the product itself for accuracy.
7.The machine operates under high voltage. Only authorized maintenance personnel or the company's maintenance software are permitted to perform repairs.
8.Unauthorized repairs will void the warranty.
Packing List
No. |
Item |
Qty |
1 |
Main engine |
1 |
2 |
220V power cord |
1 |
3 |
Charging cable (one red and one black) |
2 |
4 |
380V power cord |
1 |
5 |
The whole set of voltage acquisition line |
1 |
6 |
Touch pen |
1 |
7 |
SD card |
1 |
8 |
User Manual |
1 |
9 |
Calibration Certificate |
1 |


TO KNOW MORE ABOUT Huazheng, PLEASE CONTACT US!
Our experts will solve them in no time.