- Energy Meter Field Calibrator
-
Transformer Test Equipment
- Transformer Test Bench
- Turns Ratio Tester
- DC Resistance Tester
- Transformer Tan Delta Tester
- Sweep Frequency Response Analyzer
- Partial Discharge Tester
- CT PT Analyzer
- Transformer On-Load Tap-Changer Tester
- Short-Circuit Impedance And No-load Integrated Tester
- Winding Resistance And Turns Ratio Integrated Tester
- Transformer Capacitance And Inductance Tester
- Transformer Capacity And Characteristic Tester
- Lightning Arrester Tester
- Short-Circuit Impedance Tester
- Transformer Oil Test Equipment
- SF6 Gas Analyzer
- Secondary Injection Relay Test Set
- Resistance Tester
- Power Quality Analyzer
- HV Switch Tester
- High Voltage Test Equipment
- Cable Fault Locator
- Battery Tester
Huazheng Portable HZRC3000B Earth Resistance Soil Resistivity Tester
Introduction
HZRC3000B Earth Resistance Soil Resistivity Tester is composed of host machine, monitoring software, testing wires, auxiliary ground pillars, communication wires and others. The large LCD display of host machine is with blue backlight and bar graph indicating that can be seen clearly. At the same time it can store 300 sets of data, fulfilling historical inquiry and online real-time monitoring through monitoring software, dynamic display, alarm indicator, and with the functions like historical data access, reading, preservation, report forms, printing and so on.
HZRC3000B Earth Resistance Soil Resistivity Tester also named: Precise Earth Resistance Tester, 4-pole Earth Resistance Tester, 2/3/4-pole Earth Resistance Tester, Soil Resistivity Tester.
Technical Specifications
1. Base Conditions and Working Conditions
Influence Quantity |
Base Condition |
Working Conditions |
Remark |
Ambient Temp |
23℃±1℃ |
-10℃-40℃ |
---- |
Ambient Humidity |
40%-60% |
<80% |
---- |
Working Voltage |
9V±0.1V |
9V±1.5V |
rC、rP |
|
Auxiliary Earth Resistance |
<100Ω |
<30kΩ |
---- |
Interference Voltage |
No |
<20V |
---- |
Interference Current |
No |
<2A |
|
|
Electrode Distance when measuring R |
a>5d |
a>5d |
---- |
Electrode Distance when measuring ρ |
a>20h |
a>20h |
---- |
2. General Specification
Function |
Measurement of 2/3/4-pole earth resistance, soil resistivity, earth voltage, AC voltage |
Power Supply |
DC 9V(Zi-Mn dry battery R14S 1.5V 6 PCS, continuous standby for 300 hours ) |
Measurement Range |
Earth Resistance: 0.00Ω-30.00kΩ |
Soil Resistivity: 0.00Ωm-9000kΩm | |
|
Measuring Mode |
Precise 4-pole measurement, 3-pole measurement, simple 2-pole measurement |
|
Measuring Method |
Earth Resistance: rated current change-pole method, measurement current 20mA Max Soil Resistivity: 4-pole measurement (Wenner method) Earth Voltage: average rectification(between P(S)-ES) |
Test Frequency |
128Hz/111Hz/105Hz/94Hz(AFC) |
Short-circuit Test Current |
AC 20mA max |
|
Open-circuit Test Current |
AC 40V max |
|
Test Voltage Wave |
Sine wave |
Electrode Distance Range |
Can be set 1m-100m |
Shift |
Earth resistance: 0.00Ω-30.00kΩ, automatic shift |
Soil Resistivity: 0.00Ωm-9000kΩm, automatic shift | |
Backlight |
Blue screen backlight, suitable for dim places |
Display Mode |
4-digital super-large LCD display, blue screen backlight |
Measuring Indicator |
During measurement, LED flash indicator, LCD count down display, progress bar indicator |
|
LCD Frame Dimension |
128mm×75mm |
|
LCD Window Dimension |
124mm×67mm |
Dimension |
L×W×H: 215mm×190mm×95mm |
|
Standard Test Wire |
4 wires: each for red 20m, black 20m, yellow 10m, and green 10m |
Simple Test Wire |
2 wires: each for red 1.6m and black 1.6m |
|
Auxiliary Earthing Rod |
4 wires: Φ10mm×150mm |
Measuring Rate |
Voltage to ground: about 3 times/second |
Earth resistance, soil resistivity: about 5 seconds/time | |
|
Measuring Times |
Over 5000 times (Short-circuit test, interval time should be at least 30 seconds) |
Circuit Voltage |
below AC 600V |
RS232 Interface |
Possess RS232 interface, software supervision, storage data can be uploaded to computer, saved or printed. |
Communication Wire |
One piece of RS232 communication wire, with length 1.5m |
Data Storage |
300 sets, “MEM” icon storage indicator, flash display “FULL” icon to indicate storage is full |
Data Hold |
Data hold function: “HOLD” icon display |
Data Read |
Data read function: “READ” icon display |
|
Overflow Display |
Exceeding measuring range overflow function: “OL” icon display |
|
Interference Test |
Recognize interference signal automatically, “NOISE” icon display when interference voltage exceed 5V |
Auxiliary Earthing Test |
Can measure auxiliary earth resistance, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ) |
Alarm Function |
When measuring value exceeds alarm setting value, there is “Toot-toot-toot” alarm hint |
Battery Voltage |
When battery voltage decreases to about 7.5V, |
|
battery voltage low icon |
|
Power Consumption |
Standby: about 20mA (Backlight shut off) |
Boot and with backlight: about 45mA (25mA without backlight) | |
Measurement: about 100mA (Backlight shut off) | |
|
Weight |
Total weight: 4.5kg (including package) |
Tester: 1443g (including battery) | |
Tesing wires: 1560g | |
Auxiliary earthing rods: 935g (4pcs) | |
Working Temperature & Humidity |
-10℃-40℃, below 80%rh |
|
Storage temperature & humidity |
-20℃-60℃, below 70%rh |
Overload Protection |
Measuring earth resistance: between each interfaces of C(H)-E、P(S)-ES, AC 280V/3 seconds |
Insulation Resistance |
Over 20MΩ (between circuit and enclosure it is 500V) |
Withstanding Voltage |
AC 3700V/rms (Between circuit and enclosure) |
Electromagnetic Features |
IEC61326(EMC) |
|
Protection Type |
IEC61010-1 (CAT Ⅲ 300V、CAT IV 150V、Pollution 2), IEC61010-031, IEC61557-1 (Earth resistance), IEC61557-5 (Soil resistivity), JJG 366-2004 |
3. Intrinsic error and performance indicators under base conditions
Category |
Measurement Range |
Intrinsic Error |
Resolution |
Earth Resistance (R) |
0.00Ω-30.00Ω |
±2%rdg±3dgt |
0.01Ω |
30.0Ω-300.0Ω |
±2%rdg±3dgt |
0.1Ω |
|
300Ω-3000Ω |
±2%rdg±3dgt |
1Ω |
|
3.00kΩ-30.00kΩ |
±4%rdg±3dgt |
10Ω |
|
Soil Resistivity (ρ) |
0.00Ωm-99.99Ωm |
According to the precision of |
0.01Ωm |
100.0Ωm-999.9Ωm |
0.1Ωm |
|
1000Ωm-9999Ωm |
R (ρ=2πaR a:1 m-100m, π=3.14) |
1Ωm |
10.00kΩm-99.99kΩm |
10Ωm |
||
100.0kΩm-999.9kΩm |
100Ωm |
||
1000kΩm-9000kΩm |
1kΩm |
||
Earth Voltage |
AC 0.0-600V |
±2%rdg±3dgt |
0.1V |
Note: 1. When rC max or rP max, additional error≤±3%rdg±5dgt. (rC max: 4kΩ+100R<50kΩ, rP max: 4kΩ+100R<50kΩ)
2. When 5V interference voltage, additional error≤±5%rdg±5dgt.






TO KNOW MORE ABOUT Huazheng, PLEASE CONTACT US!
Our experts will solve them in no time.