get a quote
Inquiry
Form loading...
Products Categories
Featured Products

Huazheng Electric Manufacture HZJD-3002E Earth Resistance Tester Price

The Earth Resistance Tester, also known as a double clamp grounding resistance tester, incorporates advanced measurement methods. In addition to the traditional function of measuring grounding resistance with auxiliary grounding, it uniquely allows measurement without an auxiliary ground. The tester features a large LCD gray screen with backlight display and employs microprocessor technology. It offers precision measurement through the controlled selection of the 4-wire method, 3-wire method, simple 2-wire method, and double clamp method.

With its large-diameter current clamp design and double jaw measurement technology, the tester can perform online measurements without the need for auxiliary grounding or isolating the grounding body from the equipment. It is suitable for a wide range of applications, including telecommunications, electricity, meteorology, computer rooms, oil fields, power distribution lines, iron tower transmission lines, gas stations, and factory grounding networks.The instrument is precise, fast, simple to use, stable, and reliable.

           earth resistance tester (6)

    Introduction

    The multi-function earth / ground resistance tester (also called a ground resistance meter) is an advanced instrument that unites several measurement methods in one housing.
    In addition to the traditional four-terminal measurement with auxiliary earth spikes, it offers the unique ability to measure ground resistance without any auxiliary electrodes.
    Microprocessor-controlled, it performs accurate measurements by means of the four-wire, three-wire, simplified two-wire, selective and double-clamp methods.
    A large-diameter current clamp and true double-clamp technology allow on-line testing without auxiliary spikes and without disconnecting the earth conductor from the installation.
    The instrument is widely used in telecommunications, power utilities, meteorological stations, equipment rooms, oil fields, distribution lines, transmission towers, petrol stations, industrial earthing grids, lightning protection systems, etc.
    Testing is accurate, fast, simple, stable and reliable.
    Besides ground resistance, the meter also measures soil resistivity, earth voltage, DC voltage, DC resistance and AC current.
    A fast digital filter minimises interference, while the resistance of the auxiliary electrodes is displayed on the same screen, making it easy to spot environmental errors and ensuring that the true earth resistance is obtained.
    Up to 500 test results can be stored internally.
    Built-in Bluetooth enables wireless remote control through the mobile app; a USB port allows the same functions when the meter is connected to a PC.
    Data can be recalled, and test reports exported, at any time.
    Additional features include data hold and intelligent alarm prompts.

    Rang and Accuracy

    Measurement Function

    Range

    Accuracy

    Resolution

    two/three/four-Wire Ground Resistance(Re)

    0.000Ω19.999Ω

    ±1.5%rdg±70dgt

    0.001Ω

     

    20.00Ω199.99Ω

     

    0.01Ω

     

    200.0Ω1999.0Ω

     

    0.1Ω

     

    2.000kΩ19.999kΩ

     

     

    20.00kΩ200.00kΩ

     

    10Ω

    DC Resistance(R-)

    0.000Ω19.999Ω

    ±1.5%rdg±70dgt

    0.001Ω

     

    20.00Ω199.99Ω

     

    0.01Ω

     

    200.0Ω1999.9Ω

     

    0.1Ω

     

    2.000kΩ19.999kΩ

     

    1Ω

     

    20.00kΩ200.00kΩ

     

    10Ω

    Selective Method Ground

    0.00Ω20.00Ω

    ±2%rdg±30dgt

    0.01Ω

     

    20.0Ω200.0Ω

     

    0.1Ω

     

    0.200kΩ3.000kΩ

     

    Dual-Clamp Ground Resistance (Re)

    0.00Ω9.99Ω

    ±10%rdg±10dgt

    0.01Ω

     

    10.0Ω99.9Ω

     

    0.1Ω

     

    100Ω200Ω

    ±15%rdg±10dgt

    Soil Resistivity

    (ρ)

    0.00Ωm99.99Ωm

    ρ=2πaR (2)

    0.01Ωm

     

    100.0Ωm999.9Ωm

     

    0.1Ωm

     

    1000Ωm9999Ωm

     

    1Ωm

     

    10.00kΩm99.99kΩm

     

    10Ωm

     

    100.0kΩm999.9kΩm

     

    100Ωm

     

    1000kΩm9999kΩm

     

    1kΩm

    AC Voltage

    0.0009.999V

    ±1.5%rdg±50dgt

    0.001V

     

    10.0050.00V

     

    0.01V

    AC Current

    0.00mA9.99mA

    ±2%rdg±50dgt

    0.01mA

     

    10.00mA99.99mA

     

    0.01mA

     

    100.0mA999.9mA

     

    0.1mA

     

    1.000A9.999A

     

    1mA

     

    10.00A99.99A

     

    10mA

     

    100.0A999.9A

     

    0.1A

    DC Voltage

    0.0009.999V

    ±1.5%rdg±50dgt

    0.001V

     

    10.0050.00V

     

    0.01V

    Temperature Characteristics

    Temperature Characteristics: Add specified accuracy × 0.1/°C (when operating outside 18°C to 28°C).

    Example at 8°C: ±0.2%rdg±10dgt (base accuracy) + 0.1×10 (temperature difference) × (0.2%rdg+10dgt) = ±0.4%rdg±20dgt

    Remark:
    1. Reference conditions: accuracy with Rh Rs < 100Ω.
    Working conditions:Rh max=3kΩ+100R<50kΩ;Rs max=3kΩ+100R<50kΩ
    2.Depends on the measurement accuracy of R,π=3.14, a:1 m~100m;

    General Specification


    Ambient temperature and humidity

    23℃±5℃, below 75% rh

    Interfering voltage

    20V (should be avoided)

    Interfering current

    2A (should be avoided)

    Electrode - to - electrode distance when measuring

    R

    a5d

    Electrode - to - electrode distance when measuring ρ

    a20h

    Power Supply

    11.1V lithium - ion battery (built - in), can continuously measure in AC resistance mode when fully charged for more than 1000 times

    Screen brightness

    Controllable, users can adjust it according to the scene

    Measurement method

    Precision four - wire, three - wire method measurement, simple two - wire, selective, dual - clamp method to measure ground resistance

    Measurement method details

    Two - three - four - wire method measurement: Polarity - changing method, measurement current 42.0mA Max

    Soil resistivity: Four - pole method

    Selective measurement: Polarity - changing method, measurement current 42.0mA Max

    Dual - clamp method: Non - contact mutual induction measurement method, test current 40mA Max

    DC resistance: Polarity - changing method

    AC current: Average value rectification (clamp - type)

    Ground voltage: Average value rectification (between S - ES interfaces)

    DC voltage: Average value rectification (between S - ES interfaces)

    Test voltage waveform

    Sine wave

    Test frequency

    128Hz

    Open - circuit Test Voltage

    AC 30.0V  Max   DC 30.0V  Max

    Electrode Interval Range

    0.1m100.0m

    Display Mode

    Color - display screen

    Instrument Size

    Length×Width×Height277.2mm×227.5mm×153mm

    Current Clamp Size

    Length×Width×Height101mm×27mm×214mm

    Test Wires

    4 pieces: 15m red, 15m black, 10m yellow, 10m green each

    Simple Test Wires

    2 pieces: 1.5m yellow, 1.5m green each

    Auxiliary Grounding Rod

    4 pieces: φ10mm×200mm

    Current Clamp

    Banana plug×1, audio plug×1

    Current clamp caliber

    φ50mm

    Current Clamp Leads

    Length 2m

    Measurement Time

    AC current: about 3 times/second
    Ground - to - earth voltage: about 3 times/second
    Grounding resistance, soil resistivity: about 10 seconds/time

    USB Interface

    Has a USB interface, and stored data can be uploaded to a computer through software

    Bluetooth Connection

    Yes, real - time monitoring, data reading and other functions can be carried out on a mobile phone

    Data Line

    USB communication line, 1.5m

    Data Storage

    500 groups, "FULL" symbol indicates that the storage is full

    Overflow Display

    Over - range displays "OL" symbol

    Auxiliary Grounding Test

    Has the function of auxiliary grounding resistance test, 0.00kΩ200.00kΩ

    Alarm Function

    An alarm is issued when the measured value exceeds the set alarm value (buzzer alarm)

    Automatic Power off

    “APO” indicator, automatic power off after 15 minutes (default)

    Power Consumption

    Screen brightness: 190mA Max(maximum brightness) 140mA Min(minimum brightness)

     

    Measurement: 200mA Max(maximum brightness) 150mA Min(minimum brightness)

    Weights

    instrument 1975g(include battery)

     

    current clamp940g(2 pcs)

     

    test lead1300g(includes simple test lead)

     

    auxiliary grounding rods850g(4 rods)

    Working temperature and humidity

    -10℃40℃80%rh or below

    Storage temperature and humidity

    -20℃60℃70%rh or below

    Over-load Protection

    Measurement of ground-to -earth voltage: H - E, S - E (port - to - port) AC 280V/3 seconds

    Insulation Resistance

    20MΩ or above (between the circuit and the shell 500V)

    Withstand Voltage

    AC 3700V/rms(between the circuit and the shell)

    Electromagnetic Compatibility

    IEC61326(EMC)

    Safety Class

    IEC61010-1 (CAT III 300V, CAT IV 150V, pollution degree 2); IEC61010-031;

    IEC61557-1 (earth resistance);

    IEC61557-5 (soil resistivity);

    JJG 366-2004 (earth resistance meter);

    JJG 1054-2009 (clamp-on earth resistance meter).

    tester (3)earth resistance tester (5)

    TO KNOW MORE ABOUT Huazheng, PLEASE CONTACT US!

    Our experts will solve them in no time.