- Energy Meter Field Calibrator
-
Transformer Test Equipment
- Transformer Test Bench
- Turns Ratio Tester
- DC Resistance Tester
- Transformer Tan Delta Tester
- Sweep Frequency Response Analyzer
- Partial Discharge Tester
- CT PT Analyzer
- Transformer On-Load Tap-Changer Tester
- Short-Circuit Impedance And No-load Integrated Tester
- Winding Resistance And Turns Ratio Integrated Tester
- Transformer Capacitance And Inductance Tester
- Transformer Capacity And Characteristic Tester
- Lightning Arrester Tester
- Short-Circuit Impedance Tester
- Transformer Oil Test Equipment
- SF6 Gas Analyzer
- Secondary Injection Relay Test Set
- Resistance Tester
- Power Quality Analyzer
- HV Switch Tester
- High Voltage Test Equipment
- Cable Fault Locator
- Battery Tester
Huazheng ac dc hipot tester oil immersed high voltage testing transformer
Structure
They make up of the high quality cold rolling silicon steel piece by HZJ alternating current test transformer, HZJZ alternating and direct current amphibious light high voltage test transformer. The winding is the concentric pagoda and multilayer cylindrical type, low-voltage winding in inner, high-voltage winding in outside; Outer cover is portable which has characteristics, such as volume smallness, weight light, the shape prettiness and move convenience and so on.
Principle Of Work
This series product divides into three kinds: the alternating current is named YDJ, the alternating and direct current is named as HZJZ, meanwhile, may connecting HZJ, HZJZ with 200V switch to form series excitation transformer
Technical Parameters
1.Technical parameters of HZJ series alternating current test transformers.
Model |
Capacity(KVA) |
High Frequency Voltage Output Voltage (KV) |
High Frequency Voltage Output Current(mA) |
Low Frequency Voltage input |
Ratio |
Tempera- ture(℃) raised/ 30 minute |
||
V |
A |
|||||||
HZJ-1.5 |
1.5 |
50 |
30 |
200 |
7.5 |
500 |
10 |
|
HZJ -3 |
3 |
50 |
60 |
200 |
15 |
500 |
10 |
|
HZJ -5 |
5 |
50 |
100 |
200 |
25 |
500 |
10 |
|
HZJ -10 |
10 |
50 |
200 |
200/400 |
50/26 |
500 |
10 |
|
HZJ -20 |
20 |
50 |
400 |
400 |
53 |
500 |
10 |
|
HZJ -30 |
30 |
50 |
600 |
400 |
79 |
500 |
10 |
|
HZJ -40 |
40 |
50 |
800 |
400 |
105 |
500 |
10 |
|
HZJ -50 |
50 |
50 |
1000 |
400 |
132 |
500 |
10 |
|
HZJ -5 |
5 |
100 |
50 |
200 |
25 |
1000 |
10 |
|
HZJ -10 |
10 |
100 |
100 |
200/400 |
50/26 |
1000 |
10 |
|
HZJ -20 |
20 |
100 |
200 |
400 |
53 |
1000 |
10 |
|
HZJ -30 |
30 |
100 |
300 |
400 |
79 |
1000 |
10 |
|
HZJ-30 |
30 |
150 |
200 |
400 |
75 |
1500 |
10 |
|
HZJ -40 |
40 |
10 |
400 |
400 |
105 |
1000 |
10 |
|
HZJ -50 |
50 |
100 |
500 |
400 |
132 |
1000 |
10 |
|
HZJ-60 |
60 |
120 |
500 |
400 |
150 |
1200 |
10 |
|
HZJ -100 |
100 |
100 |
100 |
500 |
263 |
1000 |
10 |
|
HZJ -150 |
150 |
15 |
10 |
400 |
375 |
1000 |
10 |
|
HZJ -200 |
200 |
100 |
2000 |
500 |
400 |
1000 |
10 |
|
HZJ -250 |
250 |
100 |
2500 |
400 |
500 |
1000 |
10 |
|
HZJ-15 |
15 |
160 |
93 |
400 |
37.5 |
1600 |
10 |
|
HZJ -20 |
20 |
150 |
133 |
400 |
53 |
1500 |
10 |
|
HZJ -30 |
30 |
150 |
200 |
400 |
79 |
1500 |
10 |
|
HZJ -50 |
50 |
150 |
333 |
400 |
132 |
1500 |
10 |
|
HZJ -100 |
100 |
150 |
666 |
500 |
263 |
1500 |
10 |
|
HZJ -150 |
150 |
150 |
1000 |
500 |
300 |
1500 |
10 |
|
HZJ -200 |
200 |
150 |
1333 |
500 |
400 |
1500 |
10 |
|
HZJ -250 |
250 |
150 |
1666 |
400 |
500 |
1500 |
10 |
|
HZJ -30 |
30 |
200 |
150 |
400 |
79 |
2000 |
10 |
|
HZJ -30 |
30 |
160 |
187 |
400 |
37 |
1600 |
10 |
|
HZJ -50 |
50 |
200 |
250 |
400 |
132 |
2000 |
10 |
|
HZJ -100 |
100 |
200 |
500 |
400 |
263 |
2000 |
10 |
|
HZJ -150 |
150 |
200 |
750 |
500 |
300 |
2000 |
10 |
|
HZJ -200 |
200 |
200 |
1000 |
500 |
400 |
2000 |
10 |
|
HZJ -250 |
250 |
200 |
1250 |
500 |
500 |
2500 |
10 |
|
HZJ -30 |
30 |
250 |
120 |
400 |
79 |
2500 |
10 |
|
HZJ -50 |
50 |
250 |
200 |
400 |
132 |
2500 |
10 |
|
HZJ -100 |
100 |
250 |
400 |
400 |
263 |
2500 |
10 |
|
HZJ -150 |
150 |
250 |
600 |
500 |
300 |
2500 |
10 |
|
HZJ -200 |
200 |
250 |
800 |
500 |
400 |
2500 |
10 |
|
HZJ -250 |
250 |
250 |
1000 |
500 |
500 |
2500 |
10 |
|
2. Technical parameters of HZJZ alternating and direct current test transformers.
Model |
Capacity(KVA) |
High Frequency Voltage Output (KV) AC DC |
High Frequency Voltage Current (Ma) AC DC |
Low pressure input |
Ratio |
Tempera- ture(℃) raised/ 30 minute |
|||
V |
A |
||||||||
HZJZ -1.5 |
1.5 |
50 |
70 |
30 |
15 |
200 |
7.5 |
500 |
10 |
HZJZ-3 |
3 |
50 |
70 |
60 |
15 |
200 |
15 |
500 |
10 |
HZJZ -5 |
5 |
50 |
70 |
100 |
15 |
200/400 |
25 |
500 |
10 |
HZJZ-10 |
10 |
50 |
70 |
200 |
100 |
400 |
50/26 |
500 |
10 |
HZJZ -20 |
20 |
50 |
70 |
400 |
100 |
400 |
53 |
500 |
10 |
HZJ-20 |
20 |
200 |
280 |
100 |
100 |
400 |
50 |
2000 |
10 |
HZJZ-30 |
30 |
50 |
70 |
600 |
100 |
400 |
79 |
500 |
10 |
HZJZ -40 |
40 |
50 |
70 |
800 |
100 |
400 |
105 |
500 |
10 |
HZJZ-50 |
50 |
50 |
70 |
1000 |
100 |
400 |
132 |
500 |
10 |
HZJZ -5 |
5 |
100 |
140 |
100 |
50 |
200/400 |
25 |
1000 |
10 |
HZJZ -10 |
10 |
100 |
140 |
200 |
100 |
400 |
50/26 |
1000 |
10 |
HZJZ-20 |
20 |
100 |
140 |
300 |
100 |
400 |
53 |
1000 |
10 |
HZJZ -30 |
30 |
100 |
140 |
400 |
100 |
400 |
79 |
1000 |
10 |
HZJZ -40 |
40 |
100 |
140 |
600 |
100 |
400 |
105 |
1000 |
10 |
HZJZ -50 |
50 |
100 |
140 |
1000 |
100 |
400 |
132 |
1000 |
10 |
HZJ-150 |
150 |
150 |
210 |
1000 |
100 |
400 |
375 |
1500 |
10 |
With a focus on safety and efficiency, our transformer is equipped with advanced insulation and cooling systems, ensuring stable and consistent performance during prolonged testing procedures. The oil-immersed design not only enhances the transformer’s insulation capabilities but also facilitates efficient heat dissipation, contributing to its overall reliability and longevity.
This transformer is capable of delivering high voltage outputs with precision and stability, making it an ideal choice for a wide range of testing applications, including insulation testing, dielectric testing, and high voltage breakdown testing. Its versatile design and robust construction make it suitable for use in various industries, including power generation, electrical utilities, and research laboratories.
In addition to its exceptional performance, our oil immersed high voltage testing transformer is designed with user convenience in mind. It features intuitive controls and a compact footprint, making it easy to integrate into testing setups and operate with minimal training.
Overall, our oil immersed high voltage testing transformer is a reliable and efficient solution for high voltage testing needs. Its precision, durability, and user-friendly design make it an indispensable tool for professionals who require accurate and consistent high voltage testing results. Trust in our transformer to meet your high voltage testing requirements with unparalleled performance and reliability.

TO KNOW MORE ABOUT Huazheng, PLEASE CONTACT US!
Our experts will solve them in no time.