- Energy Meter Field Calibrator
-
Transformer Test Equipment
- Transformer Test Bench
- Turns Ratio Tester
- DC Resistance Tester
- Transformer Tan Delta Tester
- Sweep Frequency Response Analyzer
- Partial Discharge Tester
- CT PT Analyzer
- Transformer On-Load Tap-Changer Tester
- Short-Circuit Impedance And No-load Integrated Tester
- Winding Resistance And Turns Ratio Integrated Tester
- Transformer Capacitance And Inductance Tester
- Transformer Capacity And Characteristic Tester
- Lightning Arrester Tester
- Short-Circuit Impedance Tester
- Transformer Oil Test Equipment
- SF6 Gas Analyzer
- Secondary Injection Relay Test Set
- Resistance Tester
- Power Quality Analyzer
- HV Switch Tester
- High Voltage Test Equipment
- Cable Fault Locator
- Battery Tester
Huazheng OEM 60kv vlf cable testing equipment vlf ac hipot tester Supplier
I.Overview
|
0.1Hz voltage-withstand equipment type |
HV control method |
High voltage waveform |
Energy saving |
Noise |
Lifespan |
Electrical life |
|
mechanical |
HV mechanical switch switching polarity |
Square wave |
Not energy-saving: consume excess energy with high-power resistors |
High |
short |
Short |
|
Electronic |
HV electronic switch switching polarity |
Sine wave |
Energy saving: feed back excess power to the grid |
A little |
No lifespan, can use long-term |
Long |
Table 1 performance comparison between mechanical type and electronic type of 0.1Hz voltage withstand test equipment

II.Product Features
♢The test process is fully automated.
♢Easy to operate: simple wiring, fool operation.
♢Comprehensive protection: multiple protection (over-voltage protection, over- current protection at high and low voltage sides), rapid action (when acting)
♢Room ≤ 10ms), the instrument is safe and reliable.
♢Safety and reliability: the controller is connected with the low voltage of the high voltage generator, with photoelectric control, safe and reliable use.
♢The high and low voltage closed-loop negative feedback control circuit is adopted, and the output has no capacity rise effect.
♢Complete configuration: capacitive touch screen, LCD Chinese character display, automatic storage, automatic printing.
♢Large test range: 0.1Hz, 0.05Hz and 0.02hz multi frequency selection, large test range.
♢Small volume and light weight: it is very convenient for outdoor operation.
♢Upper computer background management software(selective assembly)
III.Technical Parameters Of Series Products

1. Output rated voltage: See table 3
2. Output frequency:0.1Hz、0.05Hz、0.02Hz、0.01Hz
3.. Carrying capacity:
5. Voltage positive, negative peak error:≤3%
6. Voltage waveform distortion degree:≤5%
7. Conditions of use: indoor, outdoor; temperature:-10℃~+40℃;humidity:≤85%RH
Note: If the portable generator is used for power supply, the generator
|
Model |
Rated voltage |
Carrying capacity |
Power source Safety tube |
Product structure and weight |
|
30/1.1 |
30kV (Peak value) |
0.1Hz,≤0.5µF |
10A |
Controller:4㎏ Voltage booster:20㎏ |
| 0.05Hz,≤1.1µF | ||||
| 0.02Hz,≤2.2µF | ||||
| 0.01Hz,≤5.5µF | ||||
|
40/1.1 |
40kV (Peak value) |
0.1Hz,≤0.5µF |
10A |
Controller:4㎏ Voltage booster:20㎏ |
| 0.05Hz,≤1.1µF | ||||
| 0.02Hz,≤2.2µF | ||||
| 0.01Hz,≤5.5µF | ||||
|
50/1.1 |
50kV (Peak value) |
0.1Hz,≤0.5µF |
15A |
Controller:4㎏ Voltage booster:40㎏ |
| 0.05Hz,≤1.1µF | ||||
| 0.02Hz,≤2.2µF | ||||
| 0.01Hz,≤5.5µF | ||||
|
60/1.1 |
60kV (Peak value) |
0.1Hz,≤0.5µF |
15A |
Controller:4㎏ Voltage booster:50㎏ |
| 0.05Hz,≤1.1µF | ||||
| 0.02Hz,≤2.2µF | ||||
| 0.01Hz,≤5.5µF | ||||
|
80/1.1 |
80kV (Peak value) |
0.1Hz,≤0.5µF |
15A |
Controller:4㎏ Voltage booster:50㎏ |
| 0.05Hz,≤1.1µF | ||||
| 0.02Hz,≤2.2µF | ||||
| 0.01Hz,≤5.5µF | ||||
|
90/1.1 |
90kV (Peak value) |
0.1Hz,≤0.5µF |
15A |
Controller:4㎏ Voltage booster:55㎏ |
| 0.05Hz,≤1.1µF | ||||
| 0.02Hz,≤2.2µF | ||||
| 0.01Hz,≤5.5µF |
electrical capacity of the instrument, and the value is shown in the table 3


TO KNOW MORE ABOUT Huazheng, PLEASE CONTACT US!
Our experts will solve them in no time.